G-4. SPRAY/BRUSH/ROLLER PAINTING IN ALL CONFINED SPACES.
a. An approved or accepted pressure demand or continuous flow Type C,
et supplied-air respirator may be
full-facepiece hood or helm used in
spray, brush, or roller painting in both indoor and outdoor confined space
(NIDLH) operations.
b. An approved or accepted pressure demand or continuous flow, Type C,
full-facepiece supplied-air respirator with auxiliary self-contained air
supply is required in operations when an--
(1) individual cannot immediately exit a confined space safely if
the primary air-supply is interrupted, or
(2) immediately life threatening toxic environment is present--
(i.e., IDLH).
c. Alternative respiratory protection for brush and roller operations
only are permitted when authorized by preventive medicine personnel (see
Table G-1).