                TG No. 144                                                             August 1987

                                                     APPENDIX E
                                                VENTILATION DESIGN


                Table. Spray Paint Ventilation Rates/Flow Rates

                                                      (cfm/sq ft face area)
                                              Air Spray                      Airless Spray
                                      Design   Operating Range         Design   Operating Range

                Spray Cabinet*
                    (4 sq ft face       200        175 - 225              125      100 - 150
                    >4 sq ft face       150        125 -4 175             100       75 - 125
                Booth
                    Vehicular           100         75 - 125               75       75 - 100
                    Walk-in             150        125 - 175              100       75 - 125


                *Cabinet located above  floor, usually at waist level. Worker's face does not
                enter the cabinet.

                Note:

                The values specified in this table are equal to or greater than those listed
                in table G-10, 29 CFR 1910.94.

























                                                          E-1